Winegard MVT-35B Manual Page 68

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 67
P a g e |
68
This procedure should be performed if the LNB arm does not line up with the stow
position bracket. This procedure requires a USB keyboard (or alternate method). The
system must be in debug mode as described earlier in this document.
It is very important that the antenna elevation is high enough that the LNB arm will
clear all obstacles.
1. The IDU screen should display “trk>”.
2. Hold down the control key (ctrl), press “t”, release both keys and then press enter.
a. The IDU screen should change to the capital “TRK>” prompt.
3. Type “dc” and press enter.
a. The IDU prompt should change to “DC>
4. Type “p 1 1500” and press enter.
a. The LNB arm should lift off of the stow tray.
b. Verify that the LNB arm will not hit any obstacles when the azimuth motor is
engaged.
c. If the LNB arm must be raised farther, type “p 1 1600”. Continue increasing the
position value until the LNB arm is at a safe elevation.
5. Center the azimuth.
a. Visually inspect the front of the antenna assembly to see if the unit is aligned
in the middle of the stow tray.
b. If the unit is aligned, skip to step 6.
c. At the “DC>” prompt, type “p 0 -500” and press enter. This will rotate the
azimuth motor clockwise past the magnetic sensor.
d. At the “DC>” prompt, enter the command “p 0 +100” and press enter. This will
rotate the azimuth counterclockwise back towards the center of the tray.
e. Continue to rotate the azimuth towards the center. It may be necessary to
decrease the amount of travel by entering values less than 100 in order to stop
at exactly the center position.
f. The system must be brought to the center position from this direction. If the
system overshoots the center position, it will be necessary to start back at step
5c above.
6. Calibrate the center (0) position.
a. From the “DC>” prompt, type “calib” and press enter.
b. Then type “y” when asked if the azimuth is at 0.
c. The azimuth should move in both directions. It may not return to the centered
position.
7. From the “DC>” menu, type “home” and press enter.
a. The IDU screen should change to the “HOME>” prompt.
8. At the “HOME>” prompt type “h” and press enter.
a. The system should go through a motor calibration.
b. Verify that when the system stows it is centered on the stow tray.
c. If the system is not centered, it will be necessary to return to step 3 and repeat
this procedure.